Condition Desc. Used
Manufacturer GE Pheonix X-Ray
Volts 208,230
Model x/argos160d
Amperes 10
Serial # NDT01F0002-105306
Length 83
Width 94
Height 84
Weight 12,200
Phase 3

This is a truck freight item which will require us to get a shipping quote. You can complete the checkout and provide payment information but you will not be charged until you agree to the freight charges. We will contact you with the freight quote. If you are providing your own shipping contact us.

X-ray Inspection system cabinet, X/Argos 160D Phoenix, fluroscopy, NDT

Mfg: GE Pheonix X-Ray

Mdl: x/argos160d

$115,000.00

Quantity: 1

Inventory #: 5851

Call 610-286-1655 with questions or shipping quotes.
REQUEST MORE INFO

This is a used fluoroscopy X-ray cabinet for performing 2D NDT inspections on large circuit boards, light castings and other parts.  The system is comprised of a 160kV x-ray source, a 6 axis manipulator positioning system, controllers, power supplies and lead shielded cabinet.  The main characteristic of this inspection system is a very large cabinet with a relatively low power X-ray source which makes the system a good fit for very large circuit boards or aluminum castings.

The overall condition of the machine is very good.  The machine will need a PC with the GE software installed to be operational.  The prior owner of the machine removed the PC for security reasons.  GE has informed us that there would be no problem getting the new PC and still fully supports the machine and could install the PC for the buyer. 

GE came to our facility and retrofitted a new window shield to satisfy a safety recall and as part of this procedure powered up the X-ray system with their diagnostic software.  The x-ray tube was determined to be fully operational with the diagnostic software and the chamber displayed no radiation leaks.  There were no faults visible with the positioning controllers and with the addition of the controlling PC there is no reason the machine would not be fully operational. 

Included is a transformer that converts 230V to the european 400V to drive the machine.  Also included is the manual.  

 

 

  • GE Phoenix X Argos
  • Specimen weight: 220 lbs.
  • Tube voltage: 10kV to 160 kV (Tube is actually 225kV rated, but machine is rated at 160kV)
  • Tube current: 5uA to 3000uA
  • Power supply: Gulmay model UC 160/10
  • Detector:
    • Thales
    • Type: TH9428 HP2H655VR13 ND
    • s/n:91114049
    • date code: 06/34
    • Camera: IMPERX
    • m/n: IMX-2M30-L
  • X-ray tube
    • XS225D000F-105306
    • Tube is actually 225kV rated, but machine is rated at 160kV
  • 6 axis sample positioning system
    • Lower slide: X-axis, stroke about 32"
    • Rotating indexer: R-axis, 15.75" dia stage
    • Vertical slide: Y-Axis (raises tube and detector): stroke about 38"
    • Horizontal slide (detector and tube mouinted on same slide with different screws on each end ): ZD-axis is the detector and ZR is the tube, total stroke about 25"
    • Tilt: Tilt-axis horizonatal slide can pivot on veritcal slide to change inspection angle
  • Door opening: 35"W x 59"H
  • Isolator feet