bannerbannerbannerbannerbannerbanner
thumb
thumb
thumb
thumb
thumb
thumb
Condition Desc. used-very good
Manufacturer Hart Scientific
Model 011
Amperes 450 watts
Serial # A3B157
Length 19
Width 14
Height 10
Weight 70
Phase 1

This is a truck freight item which will require us to get a shipping quote. You can complete the checkout and provide payment information but you will not be charged until you agree to the freight charges. We will contact you with the freight quote. If you are providing your own shipping contact us.

Fogging Test Chamber Hart 0011 plastic out gassing tester #1

Mfg: Hart Scientific

Mdl: 011

$4,800.00

Quantity: 1

Inventory #: 9685

Call 610-286-1655 with questions or shipping quotes.
REQUEST MORE INFO

This is a Hart fog tester that is used to determine the outgassing characteristics of plastics for automotive interiors.  The instument works by heating a beaker in a test well where the sample is placed and as the sample out-gasses the "fog" condiensats on the lid of the beaker due to it being cooled.  The condinsated material is then measured to determine the fogging characteristics of the plastic material.  

This particular fogging tester is self contained and provides the heat for the beaker and cooling for the lid all internally as opposed to other models that need external chillers.  Included is three glass beakers, special silcone gaskets and extra condensing plates. Unit was powered up and the wells got hot and the condensing plates got cool as they should. 

OPERATIONAL NOTE: This unit works as it should but the cooling display flashes the phrase "cut-out" inbetween showing the temperature.  After checking the manual, it appears you can set a cutout temp, but the manual then says "the cut-out temp appears in the secondary menu but it is not used. It seems this parameter was maybe once intended to be like an over/under temp setting, but then they never implemented it.  To reinterate, the cooling display screen switches from showing the temperature to the word-cut out, but this does not affect the operation of the unit.  

  • test wells:  four    
  • glass beakers:  400 ml Pyrex  5.3" x 2.82"
  • temp range:
    • test wells: 122f to 248 deg F
    • condensing plates: 68 to  104 deg F
  • setpoint accuracy: +- 0.5 deg C
  • heat time to max: 60 min
  • Used for SAE and ASTM tests such as SAE J1756, Ford BO-116-3 and GM9305P
  • The cooling display screen switches from showing the temperature to the word-cut out, but this does not affect the operation of the unit.  As reference the other two units we have do not do this but they perform exactly same as this one. 
  • OF the three of these units we have this is the only one with a CE mark